Don't Register FAL to Error Log
This parameter determines whether to register the error to the error log when a user-programmed
FAL error occurs.
Parameter
Don't regis-
OFF: Record
ter FAL to
user-defined
error log
FAL errors in
error log.
ON: Don't
record user-
defined FAL
errors in error
log.
CJ2 CPU Unit Software User's Manual
Settings
Default
OFF
This setting determines if user-
defined FAL errors created with
FAL(006) and time monitoring for
FPD(269) will be recorded in the
error log (A100 to A199). Set it to
ON to prevent these errors from
being recorded.
Function
Related flags and words
---
9 PLC Setup
9
9-11
Need help?
Do you have a question about the CJ2 CPU UNIT SOFTWARE and is the answer not in the manual?
Questions and answers
How do I retrieve fault codes from plc: CJ2M-CPU35