Address
Name
Words
Bits
A315
A315.12
Tag Memory
Error Flag (Non-
fatal Error)
(CJ2H-CPU6@-
EIP only.)
A315.13
Option Board
Error Flag
A315.15
Backup Memory
Error Flag
A316
---
High-speed
and
Counter 2 PV
A317
A318
---
High-speed
and
Counter 3 PV
A319
A320
A320.00
High-speed
Counter 2 Range
Comparison
Condition 1 In-
range Flag
A320.01
High-speed
Counter 2 Range
Comparison
Condition 2 In-
range Flag
A320.02
High-speed
Counter 2 Range
Comparison
Condition 3 In-
range Flag
A320.03
High-speed
Counter 2 Range
Comparison
Condition 4 In-
range Flag
A320.04
High-speed
Counter 2 Range
Comparison
Condition 5 In-
range Flag
A320.05
High-speed
Counter 2 Range
Comparison
Condition 6 In-
range Flag
A320.06
High-speed
Counter 2 Range
Comparison
Condition 7 In-
range Flag
A320.07
High-speed
Counter 2 Range
Comparison
Condition 8 In-
range Flag
A320.08
High-speed
Counter 2 Com-
parison In-
progress Flag
CJ2 CPU Unit Software User's Manual
Function
ON when an error occurs in the tag memory where network sym-
bols are stored.
Turns ON when the Option Board is removed while the power is
being supplied or an Option Board that is not supported is
mounted.
OFF: No error, ON: Error
ON when writing to the backup data area, source memory area,
or comment memory area in the internal flash memory fails.
This bit will turn OFF when writing is completed successfully.
Contains the PV of high-speed counter 2.
Lower 4 digits: A316, Upper 4 digits: A317
Contains the PV of high-speed counter 3.
Lower 4 digits: A318, Upper 4 digits: A319
These flags indicate whether the PV is within any of the eight
ranges when high-speed counter 2 is being operated in range-
comparison mode with upper and lower limits. The In-range
Flags, however, will be ON whenever the comparison value is
within the range regardless of the whether the high-speed counter
is set to execute the interrupt task when the range is entered or
left.
OFF: Not in range, ON: In range
This flag indicates whether a comparison operation is being exe-
cuted for high-speed counter 2.
OFF: Stopped, ON: Comparing
Appendices
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Retained
Cleared
---
Cleared
Cleared
• Written when
power is turned
ON.
• Refreshed each
cycle during over-
seeing process.
Retained
Cleared
---
Cleared
Cleared
---
Cleared
Cleared
---
Cleared
Cleared
• Refreshed each
cycle during over-
seeing process.
• Refreshed when
PRV(881) instruc-
tion is executed to
read the results of
range compari-
son.
• Refreshed when
INI(880) instruc-
tion is executed to
change PV or ring
counter maxi-
mum value.
• Refreshed when
reset.
Cleared
Cleared
Refreshed when
comparison opera-
tion starts or stops.
A-125