Omron CJ2 CPU UNIT SOFTWARE User Manual page 618

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Appendices
Address
Name
Words
Bits
A395
A395.06
File Deleted
Flags
A395.07
A395.10
ER/AER Flag for
Background Exe-
cution
A395.11
Memory Corrup-
tion Detected
Flag
A395.12
DIP Switch Pin 6
Status Flag
A400
---
Error code
A-134
Function
The system deleted the remainder of a Memory Card file that was
being updated when a power interruption occurred.
ON: File deleted
OFF: No files deleted
The system deleted the remainder of an EM file memory file that
was being updated when a power interruption occurred.
ON: File deleted
OFF: No files deleted
ON when an instruction processing error or an illegal area access
error occurs during background processing.
ON: Error. OFF (0) when power is turned ON. OFF (0) when oper-
ation starts.
OFF: No errors. OFF (0) when background processing starts.
ON when memory corruption is detected when the power supply
is turned ON.
ON: Memory corruption
OFF: Normal operation
The status of pin 6 on the DIP switch on the front of the CPU Unit
is written to this flag every cycle.
ON: Pin 6 ON
OFF: Pin 6 OFF
When a non-fatal error (user-defined FALS(006) or system error)
or a fatal error (user-defined FALS(007) or system error) occurs,
the 4-digit hexadecimal error code is written to this word. (Refer to
A-3-3 Details on Auxiliary Area Operation) on page A-161.
When two or more errors occur simultaneously, the highest error
code will be recorded.
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Cleared
Cleared
Refreshed when the
system deletes the
file.
Cleared
Cleared
Refreshed when the
system deletes the
file.
Cleared
Cleared
---
Retained
See
Refreshed when
Function
power is turned ON.
column.
Retained
See
Written every cycle.
Function
column.
Cleared
Cleared
Refreshed when
error occurs.
CJ2 CPU Unit Software User's Manual