Omron CJ2 CPU UNIT SOFTWARE User Manual page 496

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Appendices
Instruction
Mnemonic
LONG TIMER
TIML
542
(BCD)
TIMLX
553
(Binary)
MULTI-OUT-
MTIM
543
PUT TIMER
(BCD)
MTIMX
554
(Binary)
TIMER RESET
TRSET
549
A-12
Code
Symbol/Operand
TIML(542)/TIMLX(553) operates a decrementing timer
TIML(542)
with units of 0.1-s that can time up to approx. 115 days
for BCD and 49,710 days for binary (decimal or
D1
hexadecimal).
D2
Timer input
S
Timer PV
D1: Completion
Flag
D2+1, D2
D2: PV word
S: SV word
Completion Flag
(Bit 00 of D1)
TIMLX(553)
D1
D2
S
D1: Completion
Flag
D2: PV word
S: SV word
MTIM(543)/MTIMX(554) operates a 0.1-s incrementing
MTIM(543)
timer with 8 independent SVs and Completion Flags. The
setting range for the set value (SV) is 0 to 999.9 s for BCD
D1
and 0 to 6,553.5 s for binary (decimal or hexadecimal).
D2
S
D1: Completion
Flags
D2: PV word
S: 1st SV word
to
MTIMX(554)
D1
D2
S
D1: Completion
Flags
D2: PV word
S: 1st SV word
Resets the specified timer.
TRSET(549)
N
N: Timer number
Function
SV
S+1, S
Timer PV
Timer SVs
Timer input
SV 7
to
SV 2
Timer PV (D2)
SV 1
SV 0
0
Bit 7
to
Completion
Bit 2
Flags (D1)
Bit 1
Bit 0
Execution
Location
condition
Output
Required
Output
Required
D1 bits
0
to
Output
Required
CJ2 CPU Unit Software User's Manual