www.zyxel.com
When user adds zone over maximum zone number, user can not edit zone information any
more.
Condition:
1. After added 16th zone, system will be ok.
2. Edit one of the zones, it returns the error.
retval = -52011
ERROR: Zones have reached the maximum number.
60. [BUG FIX] 070821519
Symptom:
Wrong port up / down log message.
Condition:
1. Plug network line into port 4.
2. The log logged port 5 is up.
61. [BUG FIX] 070824690
Symptom:
Traffic can not go out from opt_ppp interface if opt_ppp setting use pptp and add into
WAN_TRUNK.
Condition:
1. At GUI, go to Interface -> PPP and configure opt_ppp interface.
2. Configure opt_ppp interface with pptp protocol, nailed-up and add this interface to
WAN_TRUNK to allow WAN load balance.
3. Activate opt_ppp interface.
4. The opt_ppp interface will show connected and get correct IP address.
5. By default setting, there is a policy route from lan1 and next-hop is WAN_TRUNK.
6. But traffic coming from lan1 can not go out from opt_ppp interface.
7. The opt_ppp (ppp1) interface will show dead.
62. [BUG FIX] 070831032
Symptom:
Virtual Server Summary Page shows "undefined" on original ip.
Condition:
1. Add new virtual server rule.
2. Incoming interface any.
3. Original ip any
4. Mapped IP, user define: 5.5.5.5
5. Port Mapping Type: port
56/142