ZyXEL Communications ZyWALL 1050 Release Note page 14

Firmware release note release 2.01(xl.4)
Hide thumbs Also See for ZyWALL 1050:
Table of Contents

Advertisement

www.zyxel.com
2. Create an SSL Application Object and the name is also OWA1 (Type is OWA and URL
is http://bb.com.tw)
3. In step 2, you will find that OWA1 content is changed to your latest edited status (Type:
OWA and URL is http://bb.com.tw). The original value (Type: Web Server and URL is
http://aa.com.tw) is overwritten.
23. [BUG FIX] SPR ID: 080620196
Symptom:
Inconsistent design of the SSL Application Object operation.
Condition:
There are two methods to create SSL Application Object. The fist one will be described in
step 2, and the other will be described in step 3.
1. Login ZyWALL by Firefox
2. Go to ZyWALL > Object > SSL Application and edit a SSL application object and you
won't see the preview button near URL column.
3. Go to ZyWALL > VPN > SSL VPN > Access Policy > Edit > #1 and press add button
below SSL Application List block, and pop an editing box; you will see the preview
button near URL column.
4. The correct behavior is that you won't see the preview button when you log in
ZyWALL by Firefox.
24. [BUG FIX] SPR ID: 070716802
Symptom:
A wrong CLI issued from GUI when you edit the RIP direction in interface page.
Condition:
1. Go to Interface ge4 setting page, and change the direction to "Out-Only" and apply.
2. Go to Interface ge4 setting page again, and change the direction to "BiDir" and apply.
3. GUI will issue wrong CLI "no passive-interface ge4" to change RIP direction
from "Out-only" to "BiDir".
25. [BUG FIX] SPR ID: 080708326
Symptom:
IDP log message always show wrong source port.
Condition:
1. Enable the IDP Signature Detection.
2. Telnet to ZyWALL and destination port is 22( telnet://192.168.1.1 22)
3. Type the command "/bin/sh"
4. You will find an IDP log and its source port number is always below 255.