Installing The Chassis Intrusion Detection Switch - HPE ProLiant DL180 Gen10 User Manual

Hide thumbs Also See for ProLiant DL180 Gen10:
Table of Contents

Advertisement

Installing the chassis intrusion detection switch

Procedure
1.
If installed, remove the front bezel.
2.
Power down the server.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Remove the air baffle.
6.
Attach the chassis intrusion detection switch to the chassis, connect the cable to the system board, and then route
the cable as shown in following illustration.
7.
If removed, install the secondary riser cage.
8.
Install the air baffle.
9.
Install the access panel.
10. Install the server into the rack.
11. Connect all peripheral cables to the server.
12. Connect each power cord to the server.
13. Connect each power cord to the power source.
14. Power up the server.
15. If removed, install the front bezel.
The installation is complete.
Hardware options installation
103