To configure the server to boot from a SAN, see the following guide:
https://www.hpe.com/info/boot-from-san-config-guide
•
If an HPE Smart Array SR controller is installed, use HPE Smart Storage Administrator to create arrays:
a. From the boot screen, press F10 to run Intelligent Provisioning.
b. From Intelligent Provisioning, run HPE Smart Storage Administrator.
•
If no controller is installed, do one of the following:
◦
AHCI is enabled by default. You can deploy an OS or virtualization software.
◦
Disable AHCI, enable software RAID, and then create an array:
a. From the boot screen, press F9 to run UEFI System Utilities.
b. From the UEFI System Utilities screen, select System Configurations > BIOS/Platform Configuration
(RBSU) > Storage Options > SATA Controller Options > Embedded SATA configuration > Smart
Array SW RAID Support
c. Enable SW RAID.
d. Save the configuration and reboot the server.
e. Create an array:
I.
II.
Deploy an OS or virtualization software
9.
Deploy an OS or virtualization software. Do one of the following:
•
Press F10 at the boot screen to run Intelligent Provisioning and deploy an OS.
•
Manually deploy an OS.
a. Insert the installation media.
For remote management, click Virtual Drives in the iLO remote console to mount images, drivers, or files to a
virtual folder. If a storage driver is required to install the OS, use the virtual folder to store the driver.
b. Press F11 at boot screen to select the boot device.
c. After the OS installed, update the drivers.
Register the server
10. To experience quicker service and more efficient support, register the server at the HPE website:
https://myenterpriselicense.hpe.com
Operational requirements
From the boot screen, press F9 to run UEFI System Utilities.
From the UEFI System Utilities screen, select System Configuration > Embedded Storage: HPE
Smart Storage S100i SR Gen10 > Array Configuration > Create Array
43
Setup