HPE ProLiant DL180 Gen10 User Manual page 70

Hide thumbs Also See for ProLiant DL180 Gen10:
Table of Contents

Advertisement

If the new Smart Array is the new boot device, install the device drivers.
If the new Smart Array is not the new boot device, go to the next step.
5. Ensure that users are logged off and that all tasks are completed on the server.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down
and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the
drives as failed when the server is powered up.
Procedure
1.
If installed, remove the front bezel.
2.
Power down the server.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
6.
Remove the access panel.
7.
If installing a Smart Array PCIe plug-in controller, remove the air baffle.
8.
Do one of the following:
For the Smart Array type-a modular controller, install the controller into the connector.
Hardware options installation
70

Advertisement

Table of Contents
loading

Table of Contents