Installing An Energy Pack - HPE ProLiant DL180 Gen10 User Manual

Hide thumbs Also See for ProLiant DL180 Gen10:
Table of Contents

Advertisement

IMPORTANT: If the system BIOS or controller firmware is older than the minimum recommended firmware versions,
the capacitor pack will only support one device.
The capacitor pack is fully charged after the system boots.
Minimum firmware versions
Product
HPE ProLiant DL180 Gen10 Server system ROM
HPE Smart Array SR controllers

Installing an energy pack

Prerequisites
Before you perform this procedure:
Make sure that a Smart Array P-class controller is installed.
Make sure that you have the following items available:
Storage controller backup power cable (ships with the controller)
Energy pack option
If you are installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum
firmware requirements.
Procedure
1.
If installed, remove the front bezel.
2.
Power down the server.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
6.
Remove the access panel.
7.
Remove the air baffle.
8.
Install the energy pack.
Minimum firmware version
2.00
1.90
Hardware options installation
73