17. Connect each power cord to the power source.
18. Power up the server.
19. If Intel Xeon Gold 6244 Processors are installed, enable the enhanced cooling function.
20. If removed, install the front bezel.
The installation is complete.

Enable the enhanced cooling function

The server generates more heat when Intel Xeon Gold 6244 Processor is installed. To maintain proper cooling, increase
the fan speed.
Procedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced
Options > Fan and Thermal Options > Thermal Configuration.
2. Select Enhanced CPU Cooling.
3. Save your setting.

Installing the chassis intrusion detection switch

Procedure
1.
Back up all server data.
2.
If installed, remove the bezel.
3.
Power down the server.
4.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5.
Do one of the following:
a. Extend the server from the rack.
b. Remove the server from the rack.
6.
Remove the access panel.
7.
Install the chassis intruder detection switch onto the DIMM guard and connect the cable to the system board.