4.7.10 People Present Alarm
An alarm occurs when the number of people present in a specified area exceeds the set threshold.
Note:
To use this function, make sure that people flow counting is supported by the camera and
is enabled in the VCA page. See 4 . 2 . 1 . 1 2 People Flow Counting for details.
Configure People Present Alarm
1. Go to Menu > Alarm > People Present Alarm.
2. Select the desired camera, and click Enable.
3. Set the alarm-triggered actions and arming schedule. Click the corresponding
Trigger Actions page and Arming Schedule page respectively. See 4.5.7.2 Alarm-triggered Actions
and 4.5.7.3 Arming Schedule for details.
4. Set the people present alarm threshold, which is the maximum number of people allowed in
the monitored area. An alarm occurs when the number of people present exceeds the threshold.
The valid range is from 1 to 100,000.
5. Click Apply.
View Data
In the preview page, select People Flow Counting from the drop-down list in the upper right
corner, then you can view the number of people entered, left, and present.