Commissioning
5.8 Handling the BOP 2 operator panel
5.8.3
Changing parameter values
Overview
You can modify the settings of the converter by changing the parameter values in the converter.
Precondition
The converter only permits changes to write parameters. Write parameters begin with a "P", e.g.
P45.
The value of a read-only parameter cannot be changed. Read-only parameters begin with an
"r", for example: r2.
Function description
Procedure
1. Select the menu to display and change parameter values.
2. Select the parameter filter.
– The converter only displays the most important parameters:
– The converter displays all of the parameters to you:
3. When the parameter number flashes, select the desired parameter number.
4. When the parameter value flashes, change the parameter value.
You changed a parameter value.
❒
Additional information
The converter immediately saves any changes so that they are protected against power failure.