8.19 PID technology controller
Number
r2225
r2229
Table 8-59
Number
p2216[D]
p2220[C]
p2221[C]
p2222[C]
p2223[C]
r2224
r2225
r2229
Table 8-60
Number
r2231
p2235[C]
p2236[C]
p2237[D]
p2238[D]
p2240[D]
r2245
p2247[D]
p2248[D]
r2250
294
Name
CO/BO: Technology controller fixed value selection status
word
Technology controller number actual
PID technology controller, fixed values (direct selection)
Name
Technology controller fixed value selection method
BI: Technology controller fixed value selection bit 0
BI: Technology controller fixed value selection bit 1
BI: Technology controller fixed value selection bit 2
BI: Technology controller fixed value selection bit 3
CO: Technology controller fixed value active
CO/BO: Technology controller fixed value selection status
word
Technology controller number actual
PID technology controller, motorized potentiometer
Name
Technology controller motorized potentiometer setpoint
memory
BI: Technology controller motorized potentiometer, setpoint,
raise
BI: Technology controller motorized potentiometer, setpoint,
lower
Technology controller motorized potentiometer maximum
value
Technology controller motorized potentiometer minimum
value
Technology controller motorized potentiometer start value
CO: Technology controller motorized potentiometer, setpoint
before RFG
Technology controller motorized potentiometer ramp-up time 10 s
Technology controller motorized potentiometer ramp-down
time
CO: Technology controller motorized potentiometer, setpoint
after RFG
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK
Factory setting
- %
-
Factory setting
1
0
0
0
0
- %
- %
-
Factory setting
- %
0
0
100%
-100%
0%
- %
10 s
- %