Value display
Displaying the presence of
additional digits to the
right/left of the six displayed

9.1.4 Example: Changing a parameter

Modify the parameter of the drive P21507 High speed (2.2.6) from 0 to 300.
1- From the current display switch to parameter display by setting the drive 02 on the display
2- Select the parameter of the drive you want to modify (eg: p21507 - high speed (2.2.6)) by scrolling
with the arrow keys keeping them pressed or pulse dialing
3- Move the cursor with "FN" and change the values with the arrow keys
4- Confirm the entered value by pressing "P". (2x), it will appear the number of the modified parameter
5- To proceed to the setting of another parameter, press "FN" while it is displayed the ID of the last
modified parameter and repeat from the point 2-
6- To end the setting while viewing the ID of the last parameter changed, press "FN" and confirm with
"P": starting screen will be displayed.
After the modify of the parameters of interest, it is always necessary to save the new values on
the hard memory of the Control Unit, in order to prevent a loss of data at the first shut down
(voluntary or accidental). You can proceed in 2 ways:
a) Press "P" key for 3 sec long: the actual value on the display will flash and when it becomes fixed, the
saving process on the ROM memory is terminated
Siemens S120_EN_rev06-08062017.docx