Corrective maintenance
10.2 Downloading the converter settings
5. Wait until the converter has transferred the settings from the memory card.
6. Back up the settings so that they are protected against power failure.
7. Start to commission the safety functions.
8. Enter the password for the safety functions.
9. Confirm the setting of the safety functions.
10.Exit commissioning of the safety functions.
11.Back up the settings so that they are protected against power failure.
12.Switch off the converter power supply.
13.Wait until all LEDs on the converter are dark.
14.Switch on the converter power supply again.
15.Perform a reduced acceptance test.
You have transferred the settings from the memory card to the converter.