Accessories; Line Reactor - Siemens SINAMICS G120C Operating Instructions Manual

Low voltage converters
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

Technical data
11.11 Accessories
General conditions
The following general conditions apply for the evaluations and measurements:
1. The laws for protection from electromagnetic fields in force in individual EU member states
can go beyond the minimum requirements of the EMF Directive 2013/35/EU and always take
precedence.
2. The ICNIRP 2010 limits for the workplace are the basis for the assessment.
3. The 26th BImSchV (German Federal Emission Protection Regulation) defines 100 μT (RMS)
for the assessment of active implants.
According to Directive 2013/35/EU, 500 µT (RMS) at 50 Hz is applicable here.
4. The routing of power cables has a significant impact on the electromagnetic fields that occur.
Install and operate the components inside metallic cabinets in compliance with the
documentation and use shielded motor cables.
Evaluation of the converter
The converters are normally used in machines. The assessment and testing is based on
DIN EN 12198.
Compliance with the limit values was assessed for the following frequencies:
• Line frequency 47 ... 63 Hz
• Pulse frequency, for example 4/8/16 kHz and multiples thereof, assessed up to a maximum
of 100 kHz
The indicated minimum distances apply to the head and complete torso of the human body.
Shorter distances are possible for extremities.
Table 11-15
11.11

Accessories

11.11.1

Line reactor

The assignment of a suitable line reactor to the converter is provided in the following Chapter:
Dimensions and mounting dimensions:
440
EMC-compliant setup of the machine or plant (Page 39)
Minimum distances to the converter
Individuals without active implants
Control cabinet
closed
0 cm
Forearm length (approx.
Optional components (Page 34)
Mounting base components (Page 46)
Control cabinet
open
Must be separately assessed depending on the ac‐
35 cm)
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK
Individuals with active implants
Control cabinet
closed
tive implant.
SINAMICS G120C Converters
Control cabinet
open