Installing
4.10 Connecting the interfaces for the converter control
Default setting 12: "Standard I/O with analog setpoint"
Factory setting for converters with USS interface
DO 0: p0730, DO 1:
p0731
Speed setpoint (main setpoint): p1070[0] = 755[0]
Designation in the BOP-2: Std ASP
Default setting 13: "Standard I/O with analog setpoint and safety"
DO 0: p0730, DO 1:
p0731
Speed setpoint (main setpoint): p1070[0] = 755[0]
Designation in the BOP-2: ASPS
96
AO 0: p0771[0]
DI 0: r0722.0, ..., DI 2: r0722.2
AO 0: p0771[0]
DI 0: r0722.0, ..., DI 5: r0722.5
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK
AI 0: r0755[0]
AI 0: r0755[0]