Download From Bop-2 Operator Panel - Siemens SINAMICS G120C Operating Instructions Manual

Low voltage converters
Hide thumbs Also See for SINAMICS G120C:
Table of Contents

Advertisement

10.2.2.3

Download from BOP-2 operator panel

Overview
You can transfer the converter settings that are backed up on the BOP-2 operator panel back into
the converter.
Requirement
The following preconditions apply:
• You know the password for the converter safety functions.
• The converter power supply has been switched on.
• The converter settings are not protected against copying.
Function description
Procedure
1. Attach the Operator Panel to the converter.
2. Select the download from the operator panel to the converter.
3. Start the download.
4. Wait until the download is completed.
5. After loading, check whether the converter outputs Alarm A01028.
– Alarm A01028:
– No alarm A01028: Proceed with the next step.
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK
Download with active know-how protection with copy protection (Page 401)
The loaded settings are not compatible with the converter.
Delete the alarm with p0971 = 1.
Recommission the drive.
Corrective maintenance
10.2 Downloading the converter settings