Electrical Connection - Angelo Po 0N1CP1GL User Manual

Pasta cooker
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 27
ENGLISH
WARNING: Those authorised to carry
out the connection operation must have ex-
perience acquired and certifi ed in the specif-
ic sector, in accordance with current legisla-
tion in the appliance's installation country.
The connection must make to the proper
standards and must comply with all the rel-
evant regulations and legislation.
The appliance is supplied with operating
voltage 230V/1N 50Hz ( Selector switch al-
lowed 60Hz, see electrical system diagram).
HAZARD: Before doing any work, cut
off the mains electricity supply.
Connect the appliance to the mains electricity
supply as follows:
)
If not already present, install an automatic
circuit-breaker
(A)
, close to the appliance, with
the following characteristics:
– Thermal breaker device (to adjust see table
Annexes).
14

ELECTRICAL CONNECTION

B
D
C
HANDLING AND INSTALLATION
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at mA 30.
Open the hatch (B).
)
)
Undo the screws (C) to remove the pane
Connect the circuit-breaker (A) to the termi-
)
(F)
nal board
of the appliance as shown in the
diagram and in the electrical system diagram
at the back of the manual. Use a cable with at
least H05RN-F characteristics. Tighten the ca-
H).
ble gland (
– Weight: ≥ than H05RN-F type (designation
245 IEC 57)
– Temperature of use: ≥ 70°C.
WARNING: When connecting, take
care to connect the neutral and earth lines.
)
Tighten the cable gland
)
Replace all when the operation is complete.
F
E
(D)
.
(E)
.
A
3433210_inst_GB