HANDLING AND INSTALLATION
IMPORTANT: The connection must
be made in compliance with the relevant ap-
plicable legal requirements, and using ap-
propriate and recommended materials.
)
Position the appliance un-
derneath the hood (A) (see
diagram).
IMPORTANT:
The gas supply tap must
open automatically when
the fan of the extraction sys-
tem is switched on.
WARNING: Before doing any work,
cut off the mains electricity supply.
If the type of gas to be connected is dif-
ferent from that used for testing, pro-
ceed as follows.
Turn off the gas supply tap (A).
)
)
Disconnect the electricity supply.
)
Change the burner nozzle (see page
15).
)
Change the pilot light nozzle (see
page 19).
)
Adjust the minimum setting on the
gas control valve (see page 14).
)
If necessary, adjust the burner primary
air (see page 15).
)
Remove the testing gas sticker from
the nameplate (B) and apply the new
one to identify the gas being used.
)
Remove the sticker from the appli-
ance and apply the new one (C) with
the category of the country of instal-
lation.
NOTE: After completing the
operation, check for any gas leaks or
faults.
3433210_inst_GB

CONNECTION OF FUME EXHAUST VENT

A

CONVERSION OF GAS SUPPLY

C
AL
AL
AT
AT
BE
BE
BE
BE
BG
BG
CH
B
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
A
The manufacturer has tested the appliance
with its own mains gas, identifi ed by the sticker
applied to the nameplate.
II2H3B/P: G20/20mbar, G30/30mbar
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
3P
II2H3B/P: G20/20mbar, G30/50mbar
II2H3P: G20/20mbar, G31/50mbar
II2E+3+: G20-G25/20-25mbar, G30-G31/28_30-37mbar
II2E+3B/P: G20-G25/20-25mbar, G30/30mbar
II2E+3P: G20-G25/20-25mbar, G31/37mbar
II2E+3B: G20-G25/20-25mbar, G30/30mbar
II2H3B/P: G20/20mbar, G30/30mbar
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
G20
m3/h
mbar
G31
kW
G25
m3/h
mbar
kW
G30
kW
mbar
Kg/h
G20
kW
m3/h
mbar
G31
G25
m3/h
kW
mbar
G30
kW
Kg/h
mbar
ENGLISH
IS
II2H3B/P: G20/20mbar, G30/30mbar
IS
II2H3+: G20/20mbar, G30-G31/28_30-37m
IT
II2H3+: G20/20mbar, G30-G31/28_30-37m
IT
II2H3B/P: G20/20mbar, G30/30mbar
IT
II2H3P: G20/20mbar, G31/37mbar
LT
II2H3+: G20/20mbar, G30-G31/28_30-37m
LT
II2H3B/P: G20/20mbar, G30/30mbar
LT
II2H3P: G20/20mbar, G31/37mbar
LU
II2H3B/P: G20/20mbar, G30/30mbar
LU
II2H3+: G20/20mbar, G30-G31/28_30-37m
LV
II2H3B/P: G20/20mbar, G30/30mbar
A
mbar
kW
Kg/h
~
~
kW
mbar
Kg/h
~
~
01
rif.
0051
~
CE n.
TYPE
01
rif.
0051
~
CE n.
TYPE