HANDLING AND INSTALLATION
WARNING: The connection must be
made by authorised, skilled personnel, in
accordance with the relevant legal require-
ments, using appropriate and specifi ed ma-
terials. The appliance is supplied with ope-
rating voltage 230V1N, which cannot be
switched to other values.
Direct connection to the mains requires a de-
vice ensuring disconnection from the mains,
with a contact opening distance that allows for
complete disconnection under the conditions
of overvoltage category III, in compliance with
the installation rules.
HAZARD: Before doing any work, turn
off the general power supply.
Connect the appliance to the mains electricity
supply as follows:
If not already in place, install an automatic
1)
switch-disconnector (A) close to the appli-
ance, with the following characteristics:
– Thermal release (see table in the Annex sec-
tion for adjustment instructions).
3319950_inst_GB_rev.3

ELECTRICAL CONNECTION (0*0BM1E)

A
C
B
C
D
– Reed switch curve B (IEC 60898-1).
– Residual current release set at 30 mA
Pull off the knob (B).
2)
Undo the screws (C)and remove the control
3)
panel (D).
Connect the circuit-breaker (A) to the
4)
terminal board(E) as shown in the diagram
and in the electrical system diagram at the
back of the manual and using a cable with
the following:
– Weight: ≥ than H05RN-F type (designation
245 IEC 57).
– Temperature of use: ≥ 70°C.
WARNING: When connecting, pay at-
tention to the neutral and earth cable con-
nection.
Tighten the cable gland (F).
5)
Replace all when the operation is complete.
6)
F
E
11