HANDLING AND INSTALLATION
WARNING: The connection must be
made by authorised, skilled personnel, in ac-
cordance with the applicable legal require-
ments, using appropriate and specified ma-
terials .
The appliance is supplied with operating vol-
tage 400V/3~N (230V/3 available on request)
(see attached wiring diagrams) .
Specify the correct voltage for your device; it
cannot be modified after purchase .
HAZARD: Before doing any work, turn
off the general power supply .
Connect the appliance to the mains electricity
supply as follows:
If not already present, install an automatic
1)
circuit-breaker
, close to the appliance, with
(A)
the following characteristics:
– Thermal breaker device (to adjust see table
Annexes).
– Magnetic circuit breaker curve B (IEC 60898-
1).
– Residual current protection set at mA 30.
B
3320040_inst_GB_rev.3

ELECTRICAL CONNECTION

Open the hatch (B).
2)
Undo the screws to remove the drain lever
3)
(C).
Undo the screws to remove the panel
4)
Undo the screws to remove the guard (E).
5)
Connect the circuit-breaker (A) to the terminal
6)
board (F) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual and using a cable with
the following characteristics.
– Weight: ≥ than H05RN-F type (designation
245 IEC 57).
– Temperature of use: ≥ 70°C.
tention to the neutral and earth cable con-
nection .
Replace all when the operation is complete.