Parameter Initial Value List - Fuji Electric FSZ Instruction Manual

Integral ultrasonic flowmeter s-flow
Table of Contents

Advertisement

These are factory default settings.
Setting item/7-segment display
1
Key lock
2
Zero point adjustment
3
Instantaneous flow rate decimal place
position
4
DAMPING
5
Flow unit
6
CUT OFF
7
CALIBRATION ZERO
8
CALIBRATION SPAN
9
FULL SCALE
10
Burnout
11
BURNOUT TIMER
DO1 output
12
13
DO1 contact operation
14
DO2 output
15
DO2 contact operation
16
Total rate
17
Pulse width
18
BURNOUT TIMER

3.3. Parameter initial value list

7-segment display
FSZ08
FSZ15
FSZ25
FSZ08
FSZ15
FSZ25
FSZ08
FSZ15
FSZ25
FSZ08
FSZ15
FSZ25
FSZ08
FSZ15
FSZ25
Initial value
0000 to 9999
No adjustment, clear, adjustment
,
***.*
**.**,***.*,****
***.*
***.*,****
****
***.*,****
0, 1, 3, 5, 10, 30, 60, 90 [sec]
L
0.00 to 99.99 [L/ min]
0.0 to 999.9 [L/ min]
0.0 to 999.9 [L/ min]
-99.99 to 99.99 [L/ min]
-999.9 to 999.9 [L/ min]
-999.9 to 999.9 [L/ min]
0.0 to 200.0 [%]
0.00 to 99.99 [L/ min]
0.0 to 999.9 [L/ min]
0.0 to 999.9 [L/ min]
Hold, upper, lower, zero
10 to 900
Not used, all alarms, device error, process error,
range over/pulse range over, negative flow direction,
total flow pulse
,
ON when operating, OFF when operating
,
Not used, all alarms, device error, process error,
range over/pulse range over, negative flow direction
,
ON when operating, OFF when operating
,
0.1, 1, 10, 100, 1000
0.1, 1, 10, 100, 1000
1, 10, 100, 1000, 10000
,
5, 10, 50, 100, 200
10 to 900
- 16 -
Setting range
7-segment display (selection items)
,
[L/min]
[L/min]
[L/min]
,
,
,
[SEC]
,
,
,
,
,
,
,
,
[L]
[L]
[L]
,
,
,
[msec]
[sec]
,