TECHNICAL DESCRIPTION
5.3.1

Changing The Fuses

Check that the line fuse is rated for the correct value marked on the rear
panel. Never replace with a fuse of greater value.
The fuse holder is located inside the power entry module. To change the
fuses, pull out the fuse holder from the power entry module using a small
screwdriver. The fuse holder contains two fuses, one for the line and one
for the neutral side of the mains connection. Pull out the blown fuse and
place a fuse of the correct value in its place. Use time delay 5 x 20 mm
fuses rated for 250 Volts with a current rating of 1 amp. Carefully reinsert
the fuse holder into the power entry module.

5.3.2 REPLACING THE BATTERY

The XDS encoder is fitted with a 3V 20mm diameter Lithium battery type
CR2032. This battery is used to power the clock and the article memory
while power is removed from the unit.
properly, or is not remembering the articles stored in memory when it is
powered down, the battery should be replaced according to the procedure
outlined in section 5.3.2.1.
Before attempting to change the battery remove power from the
5600MSC
Danger of explosion if battery is incorrectly replaced
Replace only with the same or equivalent type