Remove Pump Components From The Melter - Graco InvisiPac HM10 Instructions Manual

Hot melt delivery system
Table of Contents

Advertisement

616
244
F
. 79: Funnel and Air Motor Removal
IG
Remove Pump Components
from the Melter
1. Prepare for Melter Pump Repairs. Follow the
steps on page 88.
2. Remove the Piston Rod, Throat Seal, and Throat
Bearing. Follow the steps on page 94.
3A7259C
607
606
249
639
Apply threadlocker to threads
3
Torque to 90-110 in-lbs
2
3. Remove Pump Inlet Housing. Follow the steps on
page 95.
4. Remove the Pump Cylinder. Follow the steps on
page 95.
Repair
213
246
605
648
604
608
603
609
3
2
93