Upgrade Kits - Graco InvisiPac HM10 Instructions Manual

Hot melt delivery system
Table of Contents

Advertisement

Upgrade Kits

Material Tracking Kit
Used to track material consumption per product without a pattern controller.
Installation
1. See Connect Material Tracking Input, page 17, for details on hardware installation.
2. Navigate to the Material Tracking Setup screen (see Material Tracking, page 43) and check "Enable AUX
Counter" setting.
3. Navigate to the Usage Screen screen (see page 42). Verify # units counts once per product.
Part
Description
24X446
KIT, photoeye,
diffuse, 18 mm
24X447
KIT, photoeye,
pol ret ref, 18
mm
Pattern Controller Kit 24X525 and 24X526
See instruction manual 334784 for installation and
configuration instructions.
3A7259C
Contents
128073 - SENSOR, photoelectric diffuse
128071 - BRACKET, sensor mount,
straight
128070 - BRACKET, sensor mount, angled
24X449 - CABLE, M12, 4-pin, 5.0 m
128072 - SENSOR, photoelectric,
polarized
128071 - BRACKET, sensor mount,
straight
128070 - BRACKET, sensor mount, angled
128069 - SENSOR, reflector
24X449 - CABLE, M12, 4-pin, 5.0 m
Image
ti31259a
Repair Kits
ti31235a
131