Graco InvisiPac HM10 Instructions Manual page 20

Hot melt delivery system
Table of Contents

Advertisement

Installation
NOTE: The system limits current draw on incoming
power lines based on the circuit breaker size entered.
The minimum value for the setting is 15 A, and a larger
circuit breaker will allow the system to draw more
power and reduce startup time. See Technical
Specifications, page 138 for maximum system current
draw.
4. The Enable slow refill alert setting triggers a slow
refill error (L3FX) if the refill system is taking longer
than expected to transport glue into the funnel. For
more information on refill speed, see Fill/Pump
Diagnostics Screen, page 39.
5. Select the Refill setting.
Hopper auto: provides short pulses to load
material into the melter.
-
Enable this setting for On-Board Hopper
Models.
Bin auto: provides long pulses to load material into
the melter.
-
Enable this setting for Remote Vacuum Feed
Models.
-
Use with remote bin or with viscous material
that is having trouble being fed from the
on-board hopper.
Bin adapting: changes the pulse based on the
previous fill to maintain a five second refill.
NOTE: Only use Manual refill for maintenance. See
Drain the System, page 30.
Set Temperatures on the Home Screen
1. Select the Menu Symbol
2. Select the melter temperature.
3. Set the melter temperature and press the button to
apply the temperature to the channels.
20
> Home.
NOTICE
To prevent adhesive degradation, regularly disable the
heating system and do not set the hose temperature
higher than the melter temperature.
Use the + or - buttons to make small adjustments.
F
. 11: Temperature Change Screen
IG
Set or Disable a Password
Set Password
Users have the option to enable a password lock to
protect their configured settings. With a password
enabled, attempting to modify a setting brings up a
password dialog. Entering the password on any setting
unlocks all settings for two minutes.
1. Menu Symbol
2. Select Set Password.
3. Enter a four-digit numerical password.
4. Press the check mark button to save.
Disable Password
1. Menu Symbol
2. Set Password: Enter 0000 to disable the password.
3. Press the check mark button to save.
> Advanced > Display