5. Disconnect wire harness from disconnect switch
(239).
239
F
. 114
IG
6. Connect wire harness to the back side of terminal
block (22). See Electrical Schematics, page 105
for details.
22
F
. 115
IG
3A7259C
7. Route wires from the transformer base through the
grommet (18).
F
. 116
IG
8. Make electrical connections. See Electrical
Schematics, page 105 for details.
a. Connect the fan connector to AMZ J2.
b. Connect free wires labeled H1-H3 to the
disconnect switch (239).
c. Connect free wires labeled X1-X3 to the
terminal block (22).
9. Install the ADM Screen. Follow the steps on page
83.