Communications Gateway Module (CGM)
Communications Gateway Module (CGM)
Overview
The Communications Gateway Module (CGM) provides
a control link between the InvisiPac system and a
selected fieldbus. This provides the means for control
and report monitoring by an external automation
system.
NOTE: The following system network configuration files
are available at help.graco.com.
•
Add On Instructions: Allen Bradley
•
EDS file: DeviceNet or EtherNet/IP fieldbus
networks
•
GSD file: PROFIBUS fieldbus networks
•
GSDML: PROFINET fieldbus networks
NOTE: See Related Manuals, page 3. For InvisiPac
and PLC Connection Setup, verify that the PLC
parameters are set up correctly. See the Gateway Map
table. If the PLC connection parameters are not setup
correctly, the connection between the InvisiPac and
PLC will not be made.
InvisiPac Map
Gateway Map Token: 2000409
Map Name On ADM: IP MP2
Comm. Format
Input Assembly Instance:
Input Instance Size:
Output Assembly Instance:
Output Instance Size:
48
Available Internal Data
Unless stated otherwise, bytes are stored in each
instance in little endian order (byte order within
instance: most significant to least significant).
NOTE: Automation Outputs can be monitored by the
corresponding Automation Inputs to verify that the
InvisiPac received the data.
NOTE: See Automation Outputs, page 49, and the
Automation Inputs, page 60 for a full list of CGM
inputs and outputs.
Data - DINT
100
49
150
15
3A7259C