Communications Gateway
Module (CGM) and Fieldbus
Setup
Fieldbus Installation Requirements
Fieldbus-specific CGM module. See CGM Module
Housing Kits, page 126.
CGM Installation Kit. See HM10 CGM Installation
Kit 20B839, page 126.
CGM Module Housing Kits (Included in the HM10
CGM Installation Kit 20B839, page 126 or
purchased separately).
Program the CGM
Follow the instructions in manual 312864
Communications Gateway Module (CGM) to program
the CGM data map token (300) in the CGM Base.
HM10 CGM Installation Kit 20B839
Grounding Instructions
1. Install one end of the grounding wire (305) onto the
CGM base with the washer (303) and ground screw
(306).
305
F
. 110: CGM Grounding Wire
IG
2. Install the washer (303) and ground screw (304)
through the other end of the grounding wire (305).
Secure the ground screw (304) to the mounting
plate (301). See F
. 111.
IG
3A7259C
Assemble the CGM to the Mounting Plate.
1. Follow the CGM Grounding Instructions, page X.
2. Install the CGM Base to the mounting plate (301)
3. Mount the CGM Module to the CGM base.
F
Setup Fieldbus Connection
1. Connect one end of the fieldbus cable to the CGM.
2. Route the fieldbus cable through the I/O cable
3. Connect the other end of the cable to the fieldbus
CGM
Base
4. Follow the instructions in the InvisiPac CGM
303
306
with the mounting screws (302).
CGM
Module
309
305
307
308
. 111: CGM Assembly
IG
gland (207).
device.
Interface manual 3A9350 to configure the fieldbus
on the ADM and a PLC.
Repair Kits
302
CGM
Base
300
301
127