Manual Refill Dispensing
Only use Manual Refill during maintenance or if the or
automatic refill setting is not functioning properly and
cannot be fixed in a timely manner. Perform service to
the automatic feed system as soon as possible to limit
debris buildup on the feed funnel.
1. Change the refill settings to manual in the system
settings. See Set System Settings in the General
Settings, page 19.
2. Loosen the fasteners and disconnect the level
sensor to remove the top of the funnel assembly.
F
. 22: Funnel Assembly
IG
3. Fill the funnel with adhesive pellets.
NOTE: Do not fill pellets above the metal ring. Bridging
may occur if the funnel is overfilled.
F
. 23: Manual Funnel Fill
IG
4. Manually refill the funnel as needed to maintain the
required flow rate.
3A7259C

Shutdown

1. Dispense adhesive into a waste container until the
material level is down into the melter core. This will
ensure all melted pellets re-melt when the system is
re-heated.
F
. 24: Empty Funnel
IG
2. Press the power button
Screen.
F
. 25: System Inactive Home Screen