Light Tower Kit 20B729 - Graco InvisiPac HM10 Instructions Manual

Hot melt delivery system
Table of Contents

Advertisement

Light Tower Kit 20B729

226
1502
1507
F
. 104: Light Tower Kit
IG
Ref.
Description
1501 Light Tower, Red-Green, M12
1502 InvisiPac Light Tower Bracket
226
Hex Head Flange Screw
215
Flange Head Hex Nut
1505 Light Tower Panel, Painted
1506 Frame Cord Grip, 4-Position
1507 Mach Screw, MZTCM
212
Hex Lock Nut
1509 HM10 Light Tower Module
1510 Foam Gasket
3A7259C
1501
1510
1505
215
1506
1509
212
Qty.
1
1
4
4
1
1
2
2
1
1
1. Follow the procedure to Access the Electrical
Enclosure, page 83.
2. Remove the two screws on the back of the unit and
remove the vertical enclosure plate.
3. Remove the screws (203) and remove the electrical
enclosure plate (261) from the back corner of the
unit.
Vertical Enclosure Plate
F
. 105
IG
4. Install the cord grip frame (1506) as shown in F
106, and secure it with two screws.
5. Install the new light tower kit assembly by securing
the foam gasket (1510) and light tower panel (1505)
to the back corner of the unit with four screws (203).
1506
F
. 106
IG
Repair Kits
203
261
.
IG
1505,
1510