Connect Material Tracking Input

DANGER
SEVERE ELECTRIC SHOCK HAZARD
This equipment can be powered by more than 240V.
Contact with this voltage will cause death or serious
injury.
Turn off and disconnect power at main switch
before disconnecting any cables and before
servicing equipment.
A trigger sensor or dry contact input can be used to
add material tracking to InvisiPac HM10 systems. See
Repair Kits (starting on page 119) for additional details.
NOTE: See Material Tracking, page 43 for detailed
information regarding how to view setup and material
tracking information in the software.
Perform the following steps to connect a trigger sensor
to the InvisiPac system:
1. Mount the trigger sensor according to the
guidelines in the table below:
Sensor
Kit
Type
24X446
Diffuse
24X447
Retro
Reflective
2. Connect the M12 end of the supplied cable to the
trigger sensor.
3. Route the flying lead end of cable through one of
the cable grommets (CG) on the back of the
InvisiPac electrical enclosure.
3A7259C
Notes
Align sensor
perpendicular to line.
Adjust sensitivity for
proper operation.
Ensure sensor trips once
per unit.
Range: 200 mm
Align sensor
perpendicular to line.
Align reflector and sensor.
Ensure sensor trips once
per unit.
Range: 3.5 mm
4. Refer to the table and image below to connect
flying leads to the System I/O Board on AMZ #1
(P1).
VCC
Image
NPN or PNP
(do not connect both)
GND
Flying Lead Signal (color)
*NOTE: Only connect one wire (trim and terminate the
ti31255a
other wire).
J10
+
TR
-
ti31250a
VCC (brown)
PNP (black)
NPN (white)
GND (blue)
Installation
CG
P1
J10 Pin
+
TR*
-