Set PLC Settings on the ADM
F
. 16
IG
Input Options
All input options except Pump Enable/Disable are
transition-based.
Input
Unused
Input disabled
Heaters On/Off
Turn system ON
Pump
Enable or disable the pump. The
Enable/Disable
pump remains disabled if the
input signal is in the disabled
state (voltage absent)
Chanel Enable/
Enable or disable a channel
Disable
3A7259C
Action
Output Options
Output
Unused
Output disabled
System Ready
Close contact when the system
is ready
Error (Alarm)
Open contact when the alarm is
present. NOTE: alarms disable
the system heat and pump.
Error
Close contact when a deviation
(Deviation/Advisory)
or advisory is present.
Deviations and advisories do not
disable the system heater or
pump.
Maintenance Due
Close contact when selected
maintenance interval is reached.
PLC Indicators
Indicator
Input
Color
Green
Voltage Present
Gray
Voltage Absent
Setup
Action
Output
Contact Closed
Contact Open
25