Advisories And Deviations - Graco InvisiPac HM10 Instructions Manual

Hot melt delivery system
Table of Contents

Advertisement

Code
Description
V4M1
High Line Voltage:
AMZ
V6M1
Invalid Power Type:
AMZ
(C): Channel and component-specific error. See Zone (C) Lookup Table, page 74 for component error zone.
* Does not shut down system or melter zone

Advisories and Deviations

Does not shut the system down
Code
Description
A4MF
High Current:
Transformer Fan
A8FX
No Current: Fill
Solenoid
A8MF
No Current:
Transformer Fan
A8PX
No Current: Pump
Solenoid
B2AX
Low Glue per Unit
(C): Zone and component-specific error. See Zone (C) Lookup Table, page 74 for component error zone.
3A7259C
Cause
Refer to the Power Input Verification Checklist, page 73.
Refer to the Power Input Verification Checklist, page 73.
Cause
Excessive current draw
above 600mA
The transformer fan is not
connected.
The transformer fan
blocked from spinning.
The pump solenoid is
disconnected from the
AMZ.
Pump pressure is too low.
Glue per unit target needs
to be reset.
Applicator module filter may
be restricting flow.
Solution
Solution
✓Check for pinched or shorted fan wiring.
✓Replace fan.
✓See Incoming Power: 480V Models, page 106.
✓See Fill System Verification Checklist, page
73.
✓Check for damaged wiring.
✓Verify connection from fill solenoid to J6-FILL on
the AMZ circuit board.
✓Verify solenoid resistance is 97 to 115 ohms.
✓Verify the fan power cable is connected to J2 on
the AMZ circuit board. See Incoming Power:
480V Models, page 106.
✓Verify fan is free of obstructions and can spin
freely.
✓Check for damaged wiring.
✓Verify connection from pump solenoid to
J6-PUMP on the AMZ circuit board.
✓Verify the pump solenoid resistance is 97 to 115
ohms.
✓Check if pump pressure has been reduced from
desired level.
✓Navigate to material tracking page from home
screen and reset target setting.
✓Replace applicator module filter.
Error Codes
79