Graco InvisiPac HM10 Instructions Manual page 22

Hot melt delivery system
Table of Contents

Advertisement

Setup
Digital Inputs Wiring (0–30 VDC)
Item
Specifications
Digital Input
0-30 VDC
Signal Low: 0-2.5 V
Signal High: 10-30 V
1. Access the Electrical Enclosure. Follow the steps
on page 83.
2. Connect the PLC GND wire (16-28 AWG) to the
"ISO GND" terminal on J9.
PLC GND
PLC #1
PLC #2
PLC #3
PLC #4
PLC #5
PLC #6
F
. 13: Digital Inputs Wiring (J9)
IG
22
J9
ISO
GND
1
2
3
4
5
6
3. Connect an input signal wire to the desired input
terminal on J9. Terminals are labeled by input
number. Connect all remaining inputs.
NOTICE
The system I/O board and the PLC could become
damaged if connections are made to J8. Do not
connect any wires to J8 while using Digital Input type
PLC inputs. Signals on J8 are provided for Dry
Contact type inputs only.
ti31248a
3A7259C