Installation
Perform the following steps to connect a dry contact to
the InvisiPac system:
1. Route cable through one of the cable grommets
(CG) in back of the InvisiPac electrical enclosure.
2. Refer to the table and image below to connect
flying leads to the System I/O Board on AMZ #1.
J10
+
TR
-

Connect Electrical Cord

DANGER
SEVERE ELECTRIC SHOCK HAZARD
This equipment can be powered by more than 240V.
Contact with this voltage will cause death or serious
injury.
Turn off and disconnect all power before
disconnecting any cables and before servicing
equipment.
This equipment must be grounded. Connect only
to grounded power source.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
To reduce the risk of electric shock, perform the
previous Installation sections (beginning on page
11) prior to connecting the electrical cord.
1. Turn the main power switch (204) OFF.
2. Ensure that the electrical disconnect is shut off and
locked out.
3. Access the Electrical Enclosure. Follow the steps
on page 83.
4. Insert the electrical cord through the electrical
enclosure strain relief bushing (205).
18
ti31251a
NOTE: The strain relief bushing (205) fits a 0.71–0.98 in.
(18–25 mm) OD electrical cord.
5. Attach insulated ferrules to the end of each wire.
6. Connect ground wire to the chassis ground (14).
Ensure the other end of the ground wire is
connected to a true earth ground.
7. Connect power wires to the main power switch.
Tighten terminals to 7–10 in-lb (0.8–1.1 N•m).
F
. 7: Main Power Switch Wiring
IG
8. Tighten strain relief bushing (205) around electrical
cord. Install the ADM Screen. Follow the steps on
page 83.
205
204
F
. 8: Electrical Cord Connections
IG
ti31214a
20
14
3A7259C