H - The number of pump cycles that occur per minute.
L - This indicates how much material the HM10 is
dispensing per hour. This value is calculated using the
cycle rate above, the known volume of the pump, and
the specific gravity set on the Material Tracking screen.
M - The number of minutes that have passed since the
last pump cycle completed. If your application requires
a slow dispense rate, and a pump cycle takes longer
than a minute, you may see this number increase when
actively pumping. This is not a cause for concern. It is
just an artifact of how pump cycles are measured. If the
pump idle timeout feature is going to be used, this is a
good tool for choosing a value that fits your application.
I/O Diagnostics Screen
Select the Menu Symbol
the second tab.
A
A - There is a colored indicator for each discrete input.
An indicator turns green when the respective input is
activated. The functions for each input can be set on
the PLC I/O setup screen.
B - There is a colored indicator for each discrete
output. An indicator turns green when the function
configured for the respective output is true (or false in
the case of the Error (Alarm) function). The functions for
each output can be set on the PLC I/O setup screen.
C - The indicator is green when the unit counter input is
active. This input is used to track how many units the
HM10 has produced, and can be used for material
tracking information found on other screens.
D - The indicator is green when the 20B695 4 channel
upgrade USB license key is detected by the machine. If
the license key is plugged into the hub, but the
indicator is not illuminated, check all connections
40
> Diagnostics > select
B
C
D
E
between the hub and the ADM to insure a proper
connection is made.
E - The indicator is green when the 4 channel upgrade
is enabled. If the token has been removed for any
reason, the system will remain unlocked for 2 hours
before downgrading to 2 channels. If the timer expires,
it will keep the first two channels it detects, but will
remove all subsequent channels and turn the heat off.
An advisory will be present in the condition when it
can't detect the hardware license (ECUL), and an alarm
will be generated if it uninstalls any channels when the
timer expires (ER4L).
Heat Diagnostics Screen
Select the Menu Symbol
the third tab.
This screen provides information for all of the heat
zones on the system. It will show all channels,
regardless of if they are installed or not.
A
B
A - This indicates what zone the data will correspond
to.
B - Heat State: Grey is off, yellow is warming up, green
is at temperature.
C - This is the temperature of the device being
detected. If the device is not installed on the Gun Setup
Screen, but is plugged in, the temperature will still
appear. "---" indicates a valid temperature could not be
detected.
If a valid temperature is expected:
1. Check the connections in the back of the unit to
confirm the corresponding bulkhead has the right
cable connected.