Maintenance Counters: Maintenance counters count up from zero and can be reset on an individual bases by
toggling their corresponding bit high. When the maintenance counter is greater than or equal to the maintenance
interval, a corresponding advisory will be generated by the system to indicate maintenance is due. Once the
appropriate maintenance actions have been performed, a reset can be performed by toggling the corresponding
reset bit.
F
. 59
IG
Lifetime Counters: Lifetime counters are not resettable. Weight Dispensed will be displayed in the user selected
units for weight, in whole number values. Pump cycles are complete cycles, meaning a full motion in the up and
down direction. Lifetime Heat On Time and Lifetime Pump Idle Time (time the pump hasn't moved with the heat on)
are reported in hours, unlike in the resettable maintenance counters.
F
. 60
IG
Alarm Deviation Advisory Counts: This combines the total number of each type of condition into a single
bitpacked data form. While the numbers are large in the example below, they are only to represent how the data is
combined and presented in a hexadecimal value.
F
. 61
IG
3A7259C
Communications Gateway Module (CGM)
55