Maintenance
1 in. socket
602
Hex Key
602
F
. 31: Pump Outlet Filter Replacement
IG
34
Replace the Pump Inlet Filter
The pump inlet filter prevents large items from entering
the system.
1. Warm the system to operating temperature. The
adhesive must be fluid to perform this procedure.
Replace the component before the system cools.
2. Prepare Equipment for Service. Follow the steps
on page 82.
3. Remove Equipment Covers. Follow the steps on
page 82.
4. Remove the thermal insulation from the melter.
5. Remove the inlet filter plug (629) with a hex key.
6. Use pick or a small hex key to remove the inlet filter
(647).
7. Install a new pump inlet filter screen (647) into the
melter manifold.
8. Install the filter plug (629) with a hex key.
F
. 32: Pump Inlet Filter Replacement
IG
647
629
3A7259C