Repair Kits
480V Transformer Upgrade Kit 17S265
Used to upgrade to a 240 VAC system for 480 VAC
incoming power.
Ref.
Description
12
Transformer Base
13
480V Transformer
14
Hex Flange Head Nut
15
Transformer Fan Plate
16
Fan, 24 DC
17
Fan Guard
18
Grommet, 1/4 ID
21
Keps Nut
20
Flange Head Cap Screw
22
Terminal Block
23
Pan Head Screw, #6-32 x 1.25
32
Air Fitting Grommet
20
132
Transformer Installation
DANGER
Qty.
SEVERE ELECTRIC SHOCK HAZARD
1
This equipment can be powered by more than 240V.
1
Contact with this voltage will cause death or serious
4
injury.
1
Turn off and disconnect all power before servicing
1
electrical components.
1
1. Turn the main power switch (204) OFF and
1
disconnect power from the system.
4
4
2. Access the Electrical Enclosure, page 83.
1
3. Remove the knockout on the bottom of electrical
2
enclosure. Insert the grommet (18) into the
1
knockout hole.
4. Mount the terminal block (22) to the bottom of the
electrical enclosure using the terminal block
mounting screws (21).
18
21
22