Installation

Air Supply Installation

NOTICE
Oiling the air supply can damage the air controls
components. Do not install an oiler on the air supply
to the system.
System inlet air filter (60): The system must use
an air filter with a minimum flow rate of 30 scfm.
Bleed-type air valve (62): The system must use a
bleed-type ball valve that bleeds pressure
downstream when closed.
NOTE: The system air gauge lens (504) is plastic to
allow for use in food and beverage industries.
Connect to the Air Supply
1. Install the bleed-type air valve (62) and the air filter
(60) at the 1/4 NPT female system air inlet. NOTE:
Additional fittings are included with the bleed- type
air valve to use as needed.
62
F
. 5: Bleed-Type Air Valve and Air Filter Installation
IG
2. Close the bleed-type air valve (62).
16
60
62
F
. 6: Bleed-Type Air Valve Closed
IG
3. Connect an air supply line to the bleed-type air
valve (60). See Air Line Requirements, page 12.
3A7259C