Installation
Air Supply Installation
NOTICE
Oiling the air supply can damage the air controls
components. Do not install an oiler on the air supply
to the system.
•
System inlet air filter (60): The system must use
an air filter with a minimum flow rate of 30 scfm.
•
Bleed-type air valve (62): The system must use a
bleed-type ball valve that bleeds pressure
downstream when closed.
NOTE: The system air gauge lens (504) is plastic to
allow for use in food and beverage industries.
Connect to the Air Supply
1. Install the bleed-type air valve (62) and the air filter
(60) at the 1/4 NPT female system air inlet. NOTE:
Additional fittings are included with the bleed- type
air valve to use as needed.
62
F
. 5: Bleed-Type Air Valve and Air Filter Installation
IG
2. Close the bleed-type air valve (62).
16
60
62
F
. 6: Bleed-Type Air Valve Closed
IG
3. Connect an air supply line to the bleed-type air
valve (60). See Air Line Requirements, page 12.
3A7259C