Technical Specifications - Graco InvisiPac HM10 Instructions Manual

Hot melt delivery system
Table of Contents

Advertisement

Technical Specifications

Technical Specifications
InvisiPac HM10 Hot Melt Delivery System
Electrical Specifications
Incoming Power
Nominal Voltage
Model
Range
20B715,
200–240 VAC
20B716,
20B725,
200–240 VAC
20B726
350–415 VAC
20B717,
400–480 VAC
20B718,
20B727,
20B728
Channels
Channels: Models 20B715, 20B717, 20B725,
20B727
Channels: Models 20B716, 20B718, 20B726,
20B728
Minimum Applicator Wattage Per Channel
Maximum Applicator Wattage Per Channel
Minimum Hose Wattage Per Channel
Maximum Hose Wattage Per Channel
PLC
PLC Inputs
PLC Outputs
HM10
Pump Specifications
Pump
Pump Output
Pump Flow Rate
Melt Rate / Constant Throughput
138
Type
1-phase
1(Ø)
2 wire
3-Phase without neutral
3(Ø) Δ
3 wire
3-Phase with neutral
3(Ø) Y
350-415 VAC line -to-line
200-240 VAC line-to-neutral
4 wire
3-Phase without neutral
3(Ø) Δ
3 wire
US
96 lb/hr
10 lb/hr
Description
2 channels
4 channels
90 W (at 240 VAC)
400 W (at 240 VAC)
90 W (at 240 VAC)
1250 W (at 240 VAC)
6 inputs (0–30 VDC)
2 outputs (240 VAC / 24 VDC, 2 A max)
Pneumatic Piston, 12:1
19.3 cc/cycle
Max
Frequency
Amps
50/60 Hz
32 A
50/60 Hz
32 A
50/60 Hz
32 A
50/60 Hz
16 A
Metric
43.5 kg/hr
4.5 kg/hr
3A7259C

Advertisement

Table of Contents
loading

Table of Contents