Function description
Fig.: Timing diagram for EDM
Legend
t
1
t
2
Use control elements whose dynamics match the times stated at t
The function is activated or deactivated with the
4.11

Wave

With the wave function, a safety laser scanner that is to be configured in a network can be
identified more easily from its position.
When starting the automatic search for a safety laser scanner in a network the wave button
can be selected.
The device found registers with the flashing message
4.12

Rest condition

In a rest condition the functions of the safety laser scanner are deactivated to save energy.
This enables the use of the safety laser scanner with a supply voltage by battery (e.g. in an
automated guided vehicle system).
In a rest condition no safety or warning zones are monitored.
The safety laser scanner is still available for the operation and it can be switched back to
normal operation, if necessary.
4.13

Muting

The muting function can be used to suspend the safety function of the safety laser scanner
during operation, subject to special operating conditions.
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
On
OSSD
Off
24 V
EDM
0 V
After the OSSD outputs are switched on, the EDM circuit must open within 350 ms
After the OSSD outputs are switched off, the EDM circuit must close within 100 ms
t
t
1
2
1
Wiring [
54].
in the display.
and t
.
2