Muting In Two Directions - Pilz PSEN sc M 3 Series Operating Manual

Table of Contents

Advertisement

Project configuration
5.13.3

Muting in two directions

Sequence for T-muting cycle when material passes from the right-hand side
Legend
[1] Conveyed material on conveyor
[2] First muting sensor on the input side
[3] Second muting sensor on the input side
[4] PSEN sc M 3/5 series
[5] Muting lamp
[6] First muting sensor on the output side
[7] Second muting sensor on the output side
Please note the following distances and times when installing the safety laser
scanner and using the muting function.
Phase in the muting
cycle
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
[5]
[7]
[6]
[4]
Explanation
Material has already passed the first muting sensor and is being
transported on the conveyor in the direction of the second mut-
ing sensor, muting lamp off.
Material on the conveyor passes the second muting sensor
(max. 4 s after the first sensor was passed). Muting lamp
flashes, signalling the muting state.
Material on the conveyor passes the PSEN sc M 3/5 series and
the first muting sensor on the output side, muting lamp flashes,
signalling the muting state.
Material has left the area of the first muting sensor on the output
side, muting lamp is off, muting state is ended.
The next piece of material arrives at the first muting sensor.
If material is transported from the left-hand side, the cycle is re-
versed. The output side becomes the input side and the flow
starts with the second muting sensor on the output side.
[2]
[3]
[1]