Calculation Of The Overall Response Time; Switching Of Zone Sets - Pilz PSEN sc M 3.0 08-12 Operating Manual

Hide thumbs Also See for PSEN sc M 3.0 08-12:
Table of Contents

Advertisement

Project configuration
K
t
1
t
2
C
Z
R
5.2

Calculation of the overall response time

The overall response time results from the response time t1 (see
details [
tion an allowance of 10 ms per slave.
Overall response time T
T
overall
t
1
t
multiple
t
Slave
In a multiple evaluation = 3 the allowance is T
Each further increase of the multiple evaluation by 1 increases the allowance T
 by 30 ms.
tiple
5.3

Switching of zone sets

For each zone set, a unique combination of signals must be defined at the control inputs.
To prevent unintended switching of the monitored zone sets, two consecutive zone sets
must differ in at least two positions in the assigned signals at the control inputs.
In the PSENscan Configurator the automatic assignment ensures a difference in exactly
two positions.
Pilz recommends that the automatic assignment by the PSENscan Configurator is used.
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
Approach speed with which the object to be detected is nearing the danger zone in
mm/s
K = 1600 mm/s when S > 500 mm
K = 2000 mm/s when S ≤ 500 mm
Overall response time of the safety laser scanner in seconds (see
overall response time [
Time between the violation of a protective zone and signal change at the OSSD out-
put on the safety laser scanner
Machine's stopping time in seconds
The time required for the machine to stop after the signal at the OSSD output
changes
Additional distance depend on the detection capability d
C = 8(d-14 mm) with d ≤ 40 mm
C = 850 mm/s with d > 40 mm
Allowance when installing near intense light sources or reflective surfaces (see
tance to intense light sources and to reflective surfaces [
106]), an allowance of 30 ms t
overall
= t
+ t
t
1
multiple +
Slave
Response time t1 (see
Allowance 30 ms per rotation of the safety laser scanner (multiple evaluation >
2)
Addition of 10 ms per slave
34])
for each scan > 2 and with a series connec-
multiple
Technical details [
 = 30 ms.
multiple
Calculation of the
40])
Technical
106])
mul-
Dis-
| 34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psen sc m 5.5 08-126d0000166d0000176d0000206d000021

Table of Contents