Project configuration
C
5.1.2

Horizontal application with stationary danger zone

A horizontal application has been achieved when the safety laser scanner is aligned at an
angle of max. 30° with the floor level.
Fig.: Schematic representation minimum distance from the start of the protected area to the danger
zone
Legend
[1] Danger zone
[2] Area covered by the laser beam
[3] Safety laser scanner
[4] Minimum distance to the danger zone (corresponds max. to the operating range of
The following applies for these applications:
S = K * (t
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
Addition depending on the height of the scan plane, the detection capability, the am-
bient light and if necessary, additions for the installation on automated guided vehicle
systems
the safety laser scanner)
+ t
) + Z
+ Z