10kdev_.book Page 24 Friday, March 12, 1999 9:44 AM
Page Parameters
1
Automatic Barcode
reads
Barcode Reader
Label Checksum
Read Volume Tags
(barcode labels) of
unread labels
during cartridge
movement
Serial Port
Hardware
Handshake
Enable/Disable
Queued Unloads
Lock Screen
The range of acceptable values for
Note:
1.
Assigning Element Addresses
These fields are used to assign address values to the library elements and to specify the
number of available library elements. Door, drives, arms and slot addresses are input. The
number of tape drives and slots is specified.
Chapter 2
Value
Changeable Explanation
Vendor-unique Parameter;
Library Operation Switches
0
Y
Disable the barcode reader
1
Y
Enable the barcode reader
0
Y
Disable the barcode reader label
checksum
Enable the barcode reader label
1
Y
checksum
0
Y
Disables the automatic reading of
barcode labels of unread
cartridges during movement
1
Y
Enables the automatic reading of
barcode labels of unread
cartridges during movement
0
Y
Disables RS-232 RTS-CTS
Handshake
Enables RS-232 RTS-CTS
1
Y
Handshake
0
Y
Disables the library's queued
unload function
Enables the library to accept
1
Y
queued unload commands from
the host
0
Y
Unlocks all library screens
1
Y
Locks all library screens
are 0-65535 for page 0, and 0-7 for page