10kdev_.book Page 113 Friday, March 12, 1999 9:44 AM
Command Specific Information (Bytes 08 - 11)
The library does not support any commands which provide command-specific
information. The values returned for this field are 00h.
Additional Sense Code (Byte 12, bits 7-0)
This field indicates further information related to the error or exception condition as
reported in the Sense Key field. For a list of ASC values and their meanings, refer to
Appendix B of the Spectra 10000 User's Guide.
Additional Sense Code Qualifier (Byte 13, bits 7-0)
This field indicates detailed information related to the ASC. For a list of ASCQ values
and their meanings, refer to Appendix B of the Spectra 10000 User's Guide.
Field Replaceable Unit Code (Byte 14, bits 7-0)
A non-zero value in this field defines a device-specific mechanism or a unit that has failed.
A value of 0 indicates that no specific mechanism or unit has been identified to have
failed, or that the data is not available. The field-replaceable units are:
•
Library
•
Drive 1
•
Drive 2
•
Drive 4
SKSV (Byte 15, bit 7)
When the Sense Key Specific Valid bit is set to 1, the data in Byte 15, Bits 6 - 0 and Bytes
16 and 17 are valid for the command receiving the Check Condition status.
Sense Key Specific (Byte 16, bits 6-0, and Bytes 17 - 18)
When SKSV is set to 1, the information contained in this field is dependent on the value
of the Sense Key.